DAC160-2

16 bit Programmable Analog Output, Opto-Isolated ( 0-4/20 mA, 0-10VDC )

Category:

Description

“DAC16O”: 16 bit Programmable Analog Output, Opto-Isolated ( 0-4/20 mA, 0-10VDC )

(For DFW, 3590 and CPW indicators)

Built-in opto-isolated 16 bit analogue output, 0-4/20 mA, 0-10VDC (cable gland excluded). Programmable as 0…5/0…10VDC, 0…20/4…20mA through the indicator or through the PC with Dinitools. Particularly suitable for use with PLC’s and in industrial environments.
*Output -10/+10VDC upon request, only at time of order.

TECHNICAL FEATURES:

  • Output values programmable through the indicator or through the PC Dinitools: 0…5/0…10Vdc or 0…20/4…20mA. ±10Vdc upon request.
  • 16 bit resolution (65536 divisions).
  • Update frequency: from 30 to 50 Hz (depending on the weight indicator).
  • Precision: minimum +/- 0.08%, typical 0.015% in relation to the F.S.O. of the analogue output (operating temperature 25°C).
  • Maximum applicable resistance on the output in current: 350 Ω.
  • Minimum applicable resistance on the output in voltage: 10 kΩ.
  • Easily configurable through the indicator or through the PC using Dinitools.

FEATURES OF THE CONNECTABLE CABLE OF THE DAC16O:

  • Shielded 2 x 0,25 mm² cable: Maximum length for analogue output in current – 100 m. Maximum length for analogue output in voltage – 50 m.
  • Shielded 2 x 0,5 mm² cable: Maximum length for analogue output in current – 150 m. Maximum length for analogue output in voltage – 75 m.
  • Shielded 2 x 1 mm² cable: Maximum length for analogue output in current – 300 m. Maximum length for analogue output in voltage – 150 m.

NOTE: For 3590, IOEXPB option board is required, available depending on the model.