Description
“JB4QIP69K”: EQUALISED JUNCTION BOX WITH 4 INPUTS
The purpose of this guide is to familiarize the user with the installation and equalization procedure of the JB4QIP69K. We recommend that you follow the instructions carefully. Actions not indicated in this manual can compromise the proper functioning of the equipment.
TECHNICAL FEATURES
Max input voltage: 24 V
Max input current: 700 mA
Max input load cell signal: 1000 mV
Temperature effect: 50 ppm/°C
Protection rating: IP69K
Dimensions: 221 x 105 x 39 mm (l x w x h)
AISI 304 / AISI 316 stainless steel
FAQ
– Can I connect only 2 or 3 load cells?
Yes, connect the load cells starting from CELL1 connector, then close the exit holes of unused load cells with the caps provided.
– How can I connect more equalization boxes to the same weight indicator?
Generally it is recommended to use an equalization box with more channels. If it is not possible, put in parallel the equalization boxes using the connector “TO CPU”.
– Why can other unregulated load cells also be modified when adjusting trimmers?
As in any equalization board, trimmer adjustment alters the balance of load cells signal. Compared to the common equalization boxes on the market, Dini Argeo boxes have more sensitive trimmers, that allow for a more precise equalization and a smaller alteration of the adiacent load cells.